Synthes hook plate pdf

The 5th metatarsal fracture system is a comprehensively designed screw and plate system that offers surgeons a variety of options to efficiently and effectively treat complex fifth metatarsal fractures. The acumed ankle plating system 3 is designed to provide a variety of fixation options for fractures of the distal tibia and fibula. The lcp clavicle hook plate is available in different lengths and hook sizes with a left and right version for optimal sizing and screw positioning for each individual patient. Synthes veptr technical manual pdf download manualslib. Studies comparing the kirschner wire fixation and hook plate techniques have shown that the clavicle hook plate has fewer complications and allows earlier mobilization 5, 6. This site is published by the depuy synthes companies, which are solely responsible for its content. Materials and methods study design between january 2009 and march 2011, twentyfive consecutive patients with distal ulna fractures were treated surgically with a distal ulna hook plate synthes, oberdorf, switzerland.

An unusual complication and its treatment we report an unusual case of early erosion of acromion with a hookplate used for. Radiographs showed a satisfactory reduction of the fracture and metalwork. Variable angle locking plate system for treating clavicle fractures. Part of the modular synthes lcp elbow system lcp hook plate 3. The ulna hook plate provides stable distal ulna fixation through locking screws and distal hooks that contour the ulna styloid. The hook plates contain sharp hooks allowing the plate to grab the proximal fragments and help secure them back to the bone. The micro compression ft screws can be inserted between the hooks for added stability if desired. An unusual complication and its treatment saurabh odak, david burton, 2010. Evaluation of the clavicle hook plate for treatment of. Periarticular plating system, which merges locking screw technology with conventional. Synthes 11 general notes on technique determine screw choice if planning a combination of locking and cortex screws, first use a cortex screw to pull the plate to the bone. Supplemental digital content is available for this article. This allows a degree of early mobilization and avoids the need for reconstruction of the coracoclavicular ligaments 4.

Clavicle hook plates features dynamic compression screw holes accept 3. Paragon28 baby gorilla 5th metatarsal plating system. Consult depuy synthess entire lcp clavicle hook plate catalogue on medicalexpo. Radiographs showed a satisfactory reduction of the fracture and metalwork position. Open reduction and internal fixation of a distal clavicle.

Intertrochanteric reversed or transverse or with additional fracture of the medial cortex. The clavicle hook plate provides a single solution for fixation of both lateral clavicle fractures and acromioclavicular joint injuries. The clavicle hook plate is designed to address this problem by maintaining the biomechanics of the acromioclavicular joint. We report an unusual case of early erosion of acromion with a hookplate used for fixation of lateral clavicle fracture. The variax 2 clavicle plating systems provides surgeons with a comprehensive range of anatomic plating options that work with a common instrument and screw platform. All technique guides are available as pdf files at. Figure 1 a a pertrochanteric fracture ao type 31a2. Distally, an undercut allows plate bending for further adjustment. Intertrochanteric reversed or transverse or with additional fracture of the medial cortex fractures of the proximal end of the femur combined with ipsilateral shaft fractures. Ncb periprosthetic femur plate system surgical technique. Distally the plate has two pointed hooks designed to hold the styloid securely and also to provide a reference point for plate application. Part of the synthes locking compression plate lcp system.

The plate design facilitates optimal implant placement and. Case 3 16 year old, tall boy with severe outtoeing. Group 11903, award 21091 pc63950 orthopedic equipment synthes usa effective date. Scanning a patient who has this device may result in patient injury. The plates feature a preformed dual hook on one end and are available in stainless steel and titanium. Novel hybrid hook locking plate fixation for neer type v. The current authors modified the minihook plate thickness to have a low profile and contoured the plate according to the shape of the fifth metatarsal base. Direct url citations appear in the printed text and are provided in the html and pdf versions of this article on the journals web site. Please contact your sales consultant for items approved for sale in canada. Instructions for use instruments for universal small.

Place the shaft of the plate onto the superior aspect of the clavicle. The acumed ankle plating system 3 is designed to provide a variety of fixation options for rotational fractures of the distal tibia and fibula. With a good coverage of the hip, the patient and his parents requested a correction of the rotation. Ensure kirschner wires or forceps will not interfere with plate placement. Plates utilize smartlock technology which permits polyaxial screw placement. The gap between the hook arms can be used to house a lag screw, should it be necessary to stabilize the ulnar styloid fig. Two groups of patients were similar in terms of age, sex, injury mechanisms, time to surgery, and time of followup. Acromion,clavicle,hookplate, erosion,osteolysis con. Lcp hook plate depuy synthes pdf catalogs technical. The current authors modified the mini hook plate thickness to have a low profile and contoured the plate according to the shape of the fifth metatarsal base. The management options and treatment is discussed further. Request pdf early acromial erosion with the synthes hook plate.

Distal ulna hook plate fixation for unstable distal ulna. Additionally, this system includes instrumentation such as templates and tamps allowing optimal plate placement to help seat hooks if needed for reduced prominence, and to ensure hook engagement with bone. Proximal femoral locking compression plate for proximal. Use care in carefully pushing in depth gauge measuring insert hook tip. Willenegger 1991 ao manual of internal fixation, 3rd edition. Synthes locking small fragment lcp instrument and implant. Instructions for use instruments for universal small fragment. Once the plate shaft is placed on the clavicle, the end of the hook should be in. Designed in conjunction with anish kadakia, md and bruce ziran, md, the ankle plating system 3 includes seven plate families designed specifically for the treatment of ankle fractures. The hook can be fur ther secured by using a heavy, nonabsorbable suture around the posterior spinous process. Over time, osteolysis can occur around the hook as the shoulder is mobilized. Jul 21, 2010 after discussing the treatment options, the patient opted for surgical fixation.

Synthes locking small fragment lcp instrument and implant set, with selftapping screws 105. The gap between the hook arms can be used to house a lag screw, should it. Hook tip may be sharp and may pinch or tear users glove or skin. Surgical results of zones i and ii fifth metatarsal base. Ncb periprosthetic proximal femur plate surgical technique23 ncb periprosthetic distal femur plate surgical technique 33 ncb curved femur shaft plate surgical technique 39 ncb bone spacers optional 44 ncb blind screw inserts optional 44 tips and tricks for the ncb periprosthetic femur system 45 implant removal 46. If there is difficulty lowering the plate shaft onto the clavicle, then the plate with 18 mm hook depth should be used. Despite these advantages, complications can occur if the hook plate is retained. Evaluation of the clavicle hook plate for treatment of acrom. With the patient in the beach chair position using a sabre cut incision, a 3.

1108 371 1479 1352 1010 421 387 234 327 743 1054 966 1079 154 480 1316 690 1182 455 172 257 1401 1049 1034 1018 999 724 481 241 857 1341 781 749 1063 995 1120 650 1406